Xunster 500Pa flow sensor XST-LL-ADP1108 differential 5V Pressure Sensor
XST-LL-ADP1108
minimum order
1 piece
Quantity
- Model Number:XST-LL-ADP1108
- Type:AIR FLOW SENSOR
- Place of Origin:Guangdong, China
- Brand Name:Xunster
- Usage:measure gas flow
- Output:Analog
- Description:Flow sensor
- Supply voltage:5V
- Measurement range:0~500Pa
- Operating temperature:-10℃~+60℃
- Storage temperature:-40℃~+80℃
- Response time:6.6~10.1ms


The response time of the ADP1108-R has been optimized for medical ventilation applications. Mounted in a rugged, chemically inert PPS housing the ADP1108-R differential pressure sensors feature a unique dynamic range, zero offset and unsurpassed long term stability. This makes it an ideal fit for demanding yet cost sensitive OEM applications in medical and HVAC equipment. 





| Parameter | ADP1108-R | Unit | |||
| Min | Typ | Max | |||
| Measurement range | 0.25 | - | 4 | Volts | |
| 0 | - | 500 | Pa | ||
| 0 | - | 2 | Inch water | ||
| Accuracy | 20% FS to 100% FS | - | 1.5 | 3.0 | % Measured Value |
| 0 to 20% FS | - | 0.2 | 0.4 | % Full Span | |
| zero | - | 15 0.01 | 40 0.06 | mV Pa | |
| Repeatability | 100 to 500 Pa | - | 0.3 | 1.0 | % Measured Value |
| 0 to 100 Pa | - | 0.05 | 0.2 | % Full Span | |
| Null drift per year | - | 0 | 0.1 | Pa / year | |
| Additional error over temperature7 (T ≠ 23°C) | 0 to 100 % FS | - | 0.03 | 0.05 | % Measured Value4 /℃ |
| zero | - | 1 | 2 | mV/℃ | |
| Response time | 6.6 | 8.0 | 10.1 | ms | |
| Cut off frequency of internal filter | 17 | 20 | 24 | Hz | |

Comprehensive score